This chapter provides description, specification, and optional accessoriesfor the
Site Master
Series instruments. This series has two members,
as shown below. Throughout this manual, the term
Site Master
will refer to the series; whereas, the terms
Site Master S112, S113
will
refer to the applicable individual models.
Model Frequency Range
S112 5 to 1000 MHz
S113 5 to 1200 MHz
Description
The
Site Master
(Figure 1-1) is a hand held SWR/RL(standing wave
ratio/return loss) and Distance-To-Fault measurement instrument that
includes a built-in synthesized signal source and an optional power
monitor. It uses a keypad to enter data and a liquid crystal display
(LCD) to provide a graphical indication of SWR or RL over the selected
frequency range. The
Site Master S113
has a built-in distanceto-
fault capability. The
Site Master S112
, as well as model
S113
, allows
measurement data to be converted to Fault Location via the companion
Software Tools program. The
Site Master
is capable of up to
two hours of continuous operation from a fully charged internal battery.
It can also be operated from a 12.5 dc source (which will also simulta-
Specifications
Specifications
Frequency Range
5-1200MHZ
Frequency Accuracy (CW Mode)
75ppm
Frequency Resolution
100kHz
Immunity to interfering RF signals up to
+2
+10 dBm, Reflection / +30 dBc Transmission
Return Loss
Range - 0dB to 54dB, Resolution - 0.01
Specifications:
Frequency Range: 5-1200MHZ
Frequency Accuracy: (RF Source Mode) 75 parts per million @ 25°C*
Frequency Resolution: 100 kHz
SWR:
Range: 1.00 to 65.00
Resolution: 0.01
Return Loss:
Range: 0.00 to 54.00 dB
Resolution: 0.01 db
Test Port, Type N 50 Ohms
***Immunity to Interfering signals
up to the level of: –5 dBm, reflection
Maximum Input (Damage Level):
Test Port, Type N: +22 dBm
RF Detector: +20 dBm
Measurement Accuracy:
Measurement accuracy depends on calibration components. Precision calibration components have a directivity of 42 dB.
Cable Insertion Loss:
Range: 0.00 to 54.00 dB
Resolution: 0.01 dB
Frequency Reference
Aging: ±1 ppm/yr
Accuracy: ±2 ppm
Internal Memory:
Trace Memory: 40 maximum
Instrument config.:
10 setup locations
RS-232: 9 pin D-sub, three wire serial
Electromagnetic Compatibility Meets European community requirements for CE marking
Power Supply:
External DC Input: +11 to +15 Vdc, 1250 mA max.
Temperature:
Storage: –20° C to 75° C
Operation: 0° C to 50° C